INSOTECH gjør tekniske prosjekter enklere – med kompetanse og rask respons.

Page banner

EMC-kabelnippler

Viser 8 resultater

EMC-kabelnippel 288 varianter
Se Produkt

EMC-kabelnippel 2

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric,PG,NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66

EMC-kabelnippel 316 varianter
Se Produkt

EMC-kabelnippel 3

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, Neoprene (Chloroprene), EN 62444, NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66

EMC-kabelnippel 457 varianter
Se Produkt

EMC-kabelnippel 4

Vibrasjonssikker EMC-ytelse med langvarig kontakt og lav kontaktmotstand. Bevegelig fjærkontakt reduserer risiko for skade på kabelkappen; enkel montering og demontering for EMC-applikasjoner.

EMC Servo Ampacity-kabelnippel56 varianter
Se Produkt

EMC Servo Ampacity-kabelnippel

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66

EMC Servo Ampacity-kabelnippel LF28 varianter
Se Produkt

EMC Servo Ampacity-kabelnippel LF

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass (Lead-Free), Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66

EMC Snap-in kabelnippel2 varianter
Se Produkt

EMC Snap-in kabelnippel

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers) Disassembly tool (one piece included per Minimum Order Quantity), Metric, Neoprene (Chloroprene), NBR, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Polyamide 6 V2 acc. to UL 94, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66

EMC-kabelnippel med bøyebeskyttelse6 varianter
Se Produkt

EMC-kabelnippel med bøyebeskyttelse

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes. O-ring available in Metric as a standard. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, Neoprene (Chloroprene), Stainless Steel, NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66

Tungbruk EMC-kabelnippel17 varianter
Se Produkt

Tungbruk EMC-kabelnippel

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric,PG,NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66

EMC-kabelnippler med 360° elektrisk avskjerming og jordtilkobling for kabelinnføringer der elektromagnetisk interferens (EMI) må hindres. Skjermflettet kabel klemmes direkte mot huset og gir lav impedans og effektiv jordingskontinuitet. Brukes i CNC-maskiner, frekvensomformere, signalkabler og andre EMC-sensitive installasjoner. Tilgjengelig i messing og nikkelbelagt utførelse.

Vi bruker informasjonskapsler for analyse (Google Analytics og Microsoft Clarity) for å forbedre din opplevelse. Disse aktiveres kun med ditt samtykke. Les vår personvernerklæring