EMC-kabelnippler
Viser 8 resultater
88 varianterEMC-kabelnippel 2
In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric,PG,NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66
16 varianterEMC-kabelnippel 3
In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, Neoprene (Chloroprene), EN 62444, NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66
57 varianterEMC-kabelnippel 4
Vibrasjonssikker EMC-ytelse med langvarig kontakt og lav kontaktmotstand. Bevegelig fjærkontakt reduserer risiko for skade på kabelkappen; enkel montering og demontering for EMC-applikasjoner.
56 varianterEMC Servo Ampacity-kabelnippel
In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66
28 varianterEMC Servo Ampacity-kabelnippel LF
In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass (Lead-Free), Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66
2 varianterEMC Snap-in kabelnippel
In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers) Disassembly tool (one piece included per Minimum Order Quantity), Metric, Neoprene (Chloroprene), NBR, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Polyamide 6 V2 acc. to UL 94, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66
6 varianterEMC-kabelnippel med bøyebeskyttelse
In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes. O-ring available in Metric as a standard. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, Neoprene (Chloroprene), Stainless Steel, NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66
17 varianterTungbruk EMC-kabelnippel
In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric,PG,NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66
EMC-kabelnippler med 360° elektrisk avskjerming og jordtilkobling for kabelinnføringer der elektromagnetisk interferens (EMI) må hindres. Skjermflettet kabel klemmes direkte mot huset og gir lav impedans og effektiv jordingskontinuitet. Brukes i CNC-maskiner, frekvensomformere, signalkabler og andre EMC-sensitive installasjoner. Tilgjengelig i messing og nikkelbelagt utførelse.