INSOTECH gjør tekniske prosjekter enklere – med kompetanse og rask respons.

Page banner

Væsketette Fleksible Koblinger

Viser 6 resultater

HYDRUS128 varianter
Se Produkt

HYDRUS

O-ring available in Metric outer threads., Non Armoured, Lock nuts, Gaskets (Washers), Serrated Washers, Earth tags, Zone 1, Zone 21, Zone 2, Zone 22, No TC RU C-TR.AA87.B.01120/23, Metric, NPT, Chloroprene, Silicone, EN 60079-0, 1, 7, 31, Group II, Group III, IEC 60079-0, 1, 7, 31, TAE00003WU, ГОСТ 31610.0; ГОСТ IEC 60079-1, 7, 31, IMQ 13 ATEX 018X, Brass, Brass Nickel Plated, Stainless Steel, Aluminium, EX II 2GD Ex db IIC Gb, Ex eb IIC Gb, Ex tb IIIC Db, ABNT NBR IEC 60079-0, 1, 7, 31, Chloroprene: -40°C to +80°C, CML 21UKEX1474X, IECEx IMQ 13.0006X, DNV 21.0183 X, IP66, IP68 - 5 Bar, 30 min

CRUX Fleksibelt konduit36 varianter
Se Produkt

CRUX Fleksibelt konduit

Accessories must be ordered separately., Non-Armoured, ▪ Locknut ▪ Gasket (Washer) ▪ Serrated washer ▪ Earthtag, Metric, NPT, Nickel plated brass, Stainless steel (303, 316L), -60 °C to +150 °C, Silicone, IP68 - 10 Bar 30 min, IP66, Impact:Level 8

LUPUS128 varianter
Se Produkt

LUPUS

O-ring available in Metric outer threads., Non Armoured, Lock nuts, Gaskets (Washers), Serrated Washers, Earth tags, Zone 1, Zone 21, Zone 2, Zone 22, No TC RU C-TR.AA87.B.01120/23, Metric, NPT, Chloroprene, Silicone, EN 60079-0, 1, 7, 31, Group II, Group III, IEC 60079-0, 1, 7, 31, TAE00003WU, ГОСТ 31610.0; ГОСТ IEC 60079-1, 7, 31, IMQ 13 ATEX 018X, Brass, Brass Nickel Plated, Stainless Steel, Aluminium, EX II 2GD Ex db IIC Gb, Ex eb IIC Gb, Ex tb IIIC Db, ABNT NBR IEC 60079-0, 1, 7, 31, Chloroprene: -40°C to +80°C, CML 21UKEX1474X, IECEx IMQ 13.0006X, DNV 21.0183 X, IP66, IP68 - 5 Bar, 30 min

SCORPIUS128 varianter
Se Produkt

SCORPIUS

O-ring available in Metric outer threads., Non Armoured, Lock nuts, Gaskets (Washers), Serrated Washers, Earth tags, Zone 1, Zone 21, Zone 2, Zone 22, No TC RU C-TR.AA87.B.01120/23, Metric, NPT, Chloroprene, Silicone, EN 60079-0, 1, 7, 31, Group II, Group III, IEC 60079-0, 1, 7, 31, TAE00003WU, ГОСТ 31610.0; ГОСТ IEC 60079-1, 7, 31, IMQ 13 ATEX 018X, Brass, Brass Nickel Plated, Stainless Steel, Aluminium, EX II 2GD Ex db IIC Gb, Ex eb IIC Gb, Ex tb IIIC Db, ABNT NBR IEC 60079-0, 1, 7, 31, Chloroprene: -40°C to +80°C, CML 21UKEX1474X, IECEx IMQ 13.0006X, DNV 21.0183 X, IP66, IP68 - 5 Bar, 30 min

Volans fleksibelt konduit108 varianter
Se Produkt

Volans fleksibelt konduit

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric,PG,NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66

CORVUS256 varianter
Se Produkt

CORVUS

O-ring available in Metric outer threads., Non Armoured, Lock nuts, Gaskets (Washers), Serrated Washers, Earth tags, Zone 1, Zone 21, Zone 2, Zone 22, No TC RU C-TR.AA87.B.01120/23, Metric, NPT, Chloroprene, Silicone, EN 60079-0, 1, 7, 31, Group II, Group III, IEC 60079-0, 1, 7, 31, TAE00003WU, ГОСТ 31610.0; ГОСТ IEC 60079-1, 7, 31, IMQ 13 ATEX 018X, Brass, Brass Nickel Plated, Stainless Steel, Aluminium, EX II 2GD Ex db IIC Gb, Ex eb IIC Gb, Ex tb IIIC Db, ABNT NBR IEC 60079-0, 1, 7, 31, Chloroprene: -40°C to +80°C, CML 21UKEX1474X, IECEx IMQ 13.0006X, DNV 21.0183 X, IP66, IP68 - 5 Bar, 30 min

Rørgjennomføringer for fleksibelt, væsketett metallrør og plastikk-konduit i eksplosjonsutsatte soner. Kombinerer fleksibilitet for vibrasjonsisolasjon og maskinjustering med eksplosjonsbeskyttelsen som kreves i ATEX- og IECEx-godkjente installasjoner. Leveres i messing med metrisk gjenger for sone 1, 2, 21 og 22.

Vi bruker informasjonskapsler for analyse (Google Analytics og Microsoft Clarity) for å forbedre din opplevelse. Disse aktiveres kun med ditt samtykke. Les vår personvernerklæring