INSOTECH makes technical projects easier – with expertise and fast response.

Page banner
Hygienic EMC Cable Glands
Hygienic EMC Cable Glands Technical Drawing
Catalog Pages

Hygienic EMC Cable Glands

○For applications in manufacturing and packaging of food and pharmaceuticals, cleanroom technology, biotechnology, chemical industry

○Long-lasting contact by high definition contact spring

○Smooth finish prevents harmful microorganisms from adhere on the surface

○No threads are exposed

○Seal material according to FDA guideline 21 CFR 177.2600

○Cleaning of cable glands is easier, faster and less expensive Reliable strain relief due to strain relief element separated from the grommet

○Suitable for high-pressure steam cleaning. EMC Locknut included.

Specifications

Thread SizeCable ØTLSWOuter Ø 'd'Max. Height 'H'Allen SWLocknut SWShield Wire ØArticle No.BIMED Code3D FileDatasheet
M16x1,55,0 - 10,0718/1320.232.510194,0 - 9,0—BMEHG1-01-LGet FilePDF
M16x1,55,0 - 10,0718/1320.232.510194,0 - 9,0—BMEHG1-01-LGet FilePDF
M20x1,56,0 - 12,0822/1724.135.513245,0 - 11,0—BMEHG1-02-LGet FilePDF
M20x1,56,0 - 12,0822/1724.135.513245,0 - 11,0—BMEHG1-02-LGet FilePDF
M25x1,512,0 - 17,01028/2230.141173010,0 - 16,0—BMEHG1-03-LGet FilePDF
M25x1,512,0 - 17,01028/2230.141173010,0 - 16,0—BMEHG1-03-LGet FilePDF