INSOTECH makes technical projects easier – with expertise and fast response.

Page banner

Heavy Duty EMC Cable Glands

Specially designed EMC protective cable glands

Long-lasting contact by high definition contact spring Easy assembly: 1- install cable gland 2- prepare cable sheath 3- insert cable 4- tighten cap

High quality strain relief and Seal, reliable performance for EMC applications. UL and VDE certified along with various other approvals - see technical data for full details

Specifications

Thread SizeSWOuter Ø D (mm)Max. Height H (mm)Outer Thread Length TL (mm)Clamping Range Ø min-max (mm)Article No.BIMED Code3D File
M12x1,514/1415.524.263,0 - 6,5BEMH-0S
M16x1,517/182025.374,0 - 8,0BEMH-01
M16x1,520/202231.46.55,0 - 10,0BEMH-01S
M20x1,522/2224.526.586,0 - 12,0BEMH-02
M20x1,524/2426.530.2810,0 - 14,0 BEMH-02S
M25x1,524/273030810,0 - 14,0BEMH-03
M25x1,527/273032.6811,0 - 17,0BEMH-E3
M25x1,530/303339.8813,0 - 18,0BEMH-03S
M32x1,530/3437.539.8913,0 - 18,0BEMH-04
M32x1,540/4044.546.1918,0 - 25,0BEMH-04S
M40x1,540/4348.546.1918,0 - 25,0BEMH-05
M40x1,550/5055.554.5922,0 - 32,0BEMH-05S
M50x1,550/556154.5922,0 - 32,0BEMH-06
M50x1,558/586454.4927,0 - 38,0BEMH-E6
M50x1,564/647054.8934,0 - 44,0BEMH-06S
M63x1,564/687554.81434,0 - 44,0BEMH-07
M63x1,575/758356.61037,0 - 53,0BEMH-07S

Related Products

Other products in this category

EMC 2 Cable Glands88 variants
View Product

EMC 2 Cable Glands

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric,PG,NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66

EMC 3 Cable Glands16 variants
View Product

EMC 3 Cable Glands

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric and PG threads as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, Neoprene (Chloroprene), EN 62444, NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP66

EMC 4 Cable Glands57 variants
View Product

EMC 4 Cable Glands

Vibration proof EMC performance. High contact performance under vibration thanks to reduced distance between clamping seal and EMC contact fingers. Long-lasting contact by high definition contact spring. Moving spring contact offers reduced risk of sheath damage Open contact fingers when the gland cap is not tightened. Free rotational and axial movement of the cable without damaging the cable shield thanks to the open contact fingers. Low contact resistance thanks to large contact surfaces. Easy assembly and disassembly of cable. Spring closes and opens according to fastening of the cap. High quality strain relief and Seal, reliable performance for EMC applications. UL and VDE certified along with various other approvals - see technical data for full details Up-to-date international approvals. Cap/Body Material Seal Material Clamping Insert Material Contact Spring Material O-Ring Material Ingress Protection Rating NEMA Type Rating Temperature Range Thread Type Cable Type Accessories Remarks

EMC Servo Ampacity Cable Glands56 variants
View Product

EMC Servo Ampacity Cable Glands

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66

EMC Servo Ampacity Cable Glands LF28 variants
View Product

EMC Servo Ampacity Cable Glands LF

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. For NPT threads O-ring available upon request. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers), Metric, NPT, Neoprene (Chloroprene), NBR, 1, 4, 4X, 12, 13, Nickel Plated Brass (Lead-Free), Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66

EMC Snap-In Cable Glands2 variants
View Product

EMC Snap-In Cable Glands

In compliance with DIN EN 62444. We recommend the use of threaded holes and/or the use of special EMC lock nuts to ensure high quality EMC contact quality. Some approvals do not cover all sizes.O-ring available in Metric as a standard. All accessories must be ordered separately., Shielded, EMC Locknuts Dome plugs Gaskets (Washers) Disassembly tool (one piece included per Minimum Order Quantity), Metric, Neoprene (Chloroprene), NBR, Nickel Plated Brass, Permanent -20 °C to +100 °C Intermittent -40 °C to +150 °C, Polyamide 6 V2 acc. to UL 94, Special Copper Alloy, Polyamide 6 V2 acc. to UL 94, IP68 - 5 Bar 30 min, IP69, IP66

We use cookies for analytics (Google Analytics and Microsoft Clarity) to improve your experience. These are only activated with your consent. Read our privacy policy